gaoshengkeji@163.com
UL1977是用于數(shù)據(jù)、信號、控制和電力應用中使用的連接器UL認證標準,連接器UL1977認證需要進行溫升測試。UL1977溫升測試是測試連接器在通最大額定電流情況下部件的溫度變化情況,以確定連接器工作時可被接觸到的部分,是否存在溫度過高造成人身傷害的風險。
UL1977溫升測試產(chǎn)品數(shù)量
6個新樣品
UL1977溫升測試方法
- The temperature measurement is to be made on the wiring terminals of each device
溫升測試點應布在接線端子上
- The test is to continue for 4 hours even if stabilized temperatures are attained in a shorter period of time
最少連續(xù)運行4個小時,即使溫度在很短的時間內(nèi)穩(wěn)定
- Three consecutive readings, taken at 5 minute intervals indicate no further rise above the ambient temperature
三次連續(xù)讀數(shù),每次間隔5分鐘
- All contacts are to be connected in series so as to carry the same test current.
所有的端子需要串成一個回路來通相同的電流
- Tested at a draft-free area having an ambient temperature of 25 ±5°C (77 ±9°F)
測試的環(huán)境溫度應保持在25 ±5°C (77 ±9°F)
UL1977溫升測試判定標準
- The measured temperature shall not exceed the Relative Thermal Index (electrical) of the insulating material
UL:最高溫度不能超過塑料的RTI (Elec.) 值
UL+CUL:溫升不能超過30K。
溫升測試儀主要技術參數(shù):
1、最大負載試驗電壓:DC5V;
2、輸出恒定可調(diào)電流:DC 0.50~50.000~500.00A可調(diào)(1級);
3、數(shù)字顯示,精度±(0.8%讀數(shù)+0.2%量程);
4、穩(wěn)定度:1%FS,反映時間小于1S;
5、工作模式:連續(xù)/通斷;
6、試驗時間:1~99.99h,帶斷電記憶功能,時間到自動降低電流停機;
7、通斷工作模式:通斷模式通電/斷電時間:1~99.99min/小時;
8、通斷次數(shù):1~9999次,帶斷電記憶功能,次數(shù)到自動停機;
9、測溫范圍:0~260℃ 精度±0.3%讀數(shù)+1℃;分辨率:0.1℃;
10、溫度測量點:8路/16路/24路/48路可選配(包含1點測量環(huán)境溫度);
11、測溫熱電偶:美國歐米伽公司T型30AWG細絲熱電偶,長度3m,共8條;
12、溫度數(shù)據(jù)采集:由溫度數(shù)據(jù)采集儀完成,配置RS232通訊接口;
13、溫度掃描速度:1~245S所有通道;
14、溫度數(shù)據(jù)記錄:由電腦自動完成,配置電腦測試軟件;
15、軟件可設置環(huán)境溫度通道,采集數(shù)據(jù)時可自動減去環(huán)境溫度;
16、設備電源:三相AC380V±10% 50Hz,6KVA。